BLOT-LINE ENA plus

BLOT kit for the detection of specific IgG antibodies to the recombinant extractable nuclear antigens and centromere B in human serum or plasma

Description:

  • Used antigens: SS-A/Ro 52, SS-A/Ro 60, SS-B/La, Scl-70, RNP-A, RNP-C, RNP-68, SmB, SmD, Jo-1 and centromere B.
  • The recombinant antigens are applied to the nitrocellulose membrane (i.e. to the respective BLOT‑LINE (BL) strips).
  • If specific antibodies are present in the sample, they will bind to the respective antigens.
  • The complex is labelled with Conjugate and detected through a colour reaction with substrate (BCIP/NBT).
  • The kit contains 20 tests.
  • Short incubation periods, total assay time: approximately 1.5 h.
  • High sensitivity and specificity.
  • All reagents are supplied in working strength.
  • The kit may be used sequentially for smaller batches of samples (reagents are provided in sufficient quantities).
  • All BL strips are equipped with the CUT-OFF band to check functionality and sensitivity of the kits.
  • Positive and Negative controls included enabling validation of the tests.
  • Blotting trays included.
  • Evaluation of results – clear criteria using Evaluation table.
  • Software evaluation of results is also possible – IMUNOBLOT II software (TEST-LINE).
  • Expiry period: 12 months from the production date.

Applications:

  • Laboratory test for the detection of antinuclear antibodies, confirmatory test to ELISA.

Brief assay procedure:

  1. Dilute serum/plasma samples (1:50)
  2. Pipette diluted samples and controls into the channels of the tray and insert the BL strips.
  3. Incubate for 30 min at room temperature using a shaker.
  4. Wash 3 times for 5 min.
  5. Add Conjugate.
  6. Incubate for 30 min at room temperature using a shaker.
  7. Wash 3 times for 5 min.
  8. Add substrate (BCIP/NBT).
  9. Incubate for 15 min at room temperature using a shaker.
  10. Wash twice for 5 min in distilled water.
  11. Dry the strips and evaluate results using the validation strip enclosed or using IMUNOBLOT II software.


word documentSafety sheets

For further information please contact TEST-LINE E-mail: trade@test-line.cz
Tel.: +420 549 121 209 (218)
Send us message using our Contact Form.
SEARCHING OF QUALITY DATA SHEETS

Enter the TEST-LINE lot number (6 – 8 marks,
printed on the outward packing of the product)
Quality data Sheets for CF

CERTIFICATES
CONTACTS Orders: +420 541 243 390 (FAX)
order@test-line.cz

Trade Dpt.: +420 549 121 209 (218)
trade@test-line.cz

Quality Control: +420 549 121 219
quality@test-line.cz
DISTRIBUTION

We offer our products worldwide.

Are you interested in?

Contact us
  Enter the TEST-LINE lot number for following products:

 

Trade teritory limited.
Please contact TEST-LINE for further information.

E-mail: order@test-line.cz
Phone: +420 549 121 209